Product Description
The Square-Tube Guardrail Post is a hollow steel section standing between the corrugated guardrail beam and the road foundation, holding the two-wave or three-wave rail at the designed installation height and transferring traffic loads down into the foundation. The closed tube gives flat faces for welding brackets or base plates and clean bearing surfaces for the connection bolts, and the whole post is hot-dip galvanized so the zinc layer separates the steel from rain, frost, humid air, and salt-bearing outdoor atmospheres. It is used on rural, national, and provincial roads, on highways and mountain alignments, and on coastal or high-rainfall roads where uncoated supports would corrode within a short service life, and it is paired with W-beam panels, spacer blocks, brackets, and connecting bolts rather than treated as a standalone replacement part.
On long framework contracts the risk is consistency across batches: posts from one delivery to the next can drift in cut length, hole position, or coating thickness, and field crews end up sorting posts and refitting brackets on site. Our galvanized posts run on the same forming, cutting, and hot-dip galvanizing line in continuous batches, so the section, length, hole pattern, and zinc coat stay matched order after order, and concentrated raw-material preparation keeps unit pricing favorable on large repeat contracts. For European-requirement projects the coating can be controlled to at least 600 g/m² with reference to EN ISO 1461, with the average thickness, local minimum value, and sampling method fixed in the contract instead of left as a general heavy galvanized description.

Specifications
|
Parameter |
Specification |
|
Product Form |
Hollow square steel tube post for corrugated guardrail systems |
|
Outer Tube Dimensions |
Project-specified; To Be Confirmed |
|
Wall Thickness |
Project-specified; To Be Confirmed |
|
Post Length |
Project-specified; To Be Confirmed |
|
Anti-Corrosion Process |
Hot-dip galvanized |
|
Zinc Coating Reference |
European-project requirements may specify at least 600 g/m² per EN ISO 1461 |
|
Matching Components |
Two-wave W-beams, three-wave panels, spacer blocks, brackets, connecting bolts |
|
Suitable Environments |
Rainy, mountain, cold, humid, and coastal road areas |
|
Inspection Items |
Steel material, wall thickness, length, hole positions, coating condition, external appearance |
Applications
1. National and Provincial Highway Rehabilitation - Galvanized square posts keep replacement supports visually uniform along a long alignment, with no painting maintenance needed over years of outdoor exposure.
2. Coastal and High-Rainfall Roads - Salt-laden air and frequent rain attack bare steel fastest; the zinc layer on the post, bolts, and spacer blocks protects the whole connection rather than only the visible beam face.
3. Industrial Park and Urban Roads - Exhaust dust and airborne chemical residues accelerate corrosion; consistently galvanized posts reduce maintenance call-outs on roads that stay open to traffic.
4. Long-Term Framework Contracts - Repeated batches with matched dimensions and coating records simplify receiving inspection and spare-part ordering over the service life of the project.

Customization
Tube size, wall thickness, post length, hole positions, welded brackets, and base plates can be produced to project drawings, and the galvanizing requirement can be controlled in micrometres or grams per square metre according to the site environment and contract. Product marking, outer packaging, and mixed specification combinations can be customized. OEM and ODM orders are accepted, and customized posts enter mass production only after first-piece confirmation.



Packaging & Transportation
For export, posts are sorted by specification, bundled with steel straps, and protected with waterproof film and rubber separators, while bolts and small accessories are packed separately. Timber supports are used inside the container to reduce movement and collision during transit, and pallets can be arranged on request. The loading process is recorded for every export shipment, and transport damage should be reported with photos, videos, and shipping documents. EXW is our preferred trade term.


FAQ
Q1: How should we specify the zinc coating for square-tube posts?
A1: State the galvanizing process, the zinc unit (micrometres or grams per square metre), the average and local minimum requirement, the sampling method, and the corrosion protection required for matching fasteners. European projects may specify at least 600 g/m² with reference to EN ISO 1461, but the final value is confirmed per contract, steel thickness, and site environment.
Q2: What is the lead time for galvanized posts?
A2: Standard posts normally require about 3–5 days for production. Drawing-customized or non-standard posts generally require about 10–15 days after drawing confirmation, and the agreed delivery time can be written into the contract; repeat orders of the same specification are scheduled faster.
Q3: Can one damaged post be replaced without removing the whole barrier section?
A3: Yes. When a local collision damages a support, the affected post can be replaced according to site conditions while the beam line and neighboring posts stay in place, provided the replacement post matches the section and hole pattern of the original design.
Hot Tags: square-tube guardrail post, China square-tube guardrail post manufacturers, suppliers, factory, C section steel post, Galvanized Steel Guardrail Posts, guardrail post slotted, median steel guardrail post, U channel steel post, U section support post